HOME CONTENTS BACK PRINT EMERGENCY PROCEDURES

Right Direct Panel (1 of 2)

Reset
MALFSResets all active and armed malfunctions, and restores all failed radio stations.
SYSTEMResets all systems to default configuration.
TEMPResets all aircraft systems temperatures to normal, according to the system configuration.
Freeze
ALTFreezes aircraft altitude at current setting. All other aerodynamic and aircraft systems remain operational.
FLIGHTFreezes aerodynamic parameters (aircraft speed, attitude, altitude and geographical position). Aircraft systems remain operational.
FUELFreezes fuel quantities at current value. Engine fuel flows unaffected, but no fuel depletion occurs.
POSFreezes aircraft at current geographical location. All other aerodynamic and aircraft systems remain operational.
Ground Service
EXT POWERSimulates connection of external power supply when aircraft is stationary on the ground.
EXT AIRSimulates connection of external air supply when aircraft is stationary on the ground.
ENG STARTStarts all engines immediately regardless of air, fuel, oil or electrical supplies, provided the fuel cut-off switches are in the flow position. Engines will continue to run if fuel and oil supplies are available.
APU STARTStarts APU immediately, regardless of air, fuel, oil or electrical supplies, provided APU master switch is on. APU will continue to run if fuel and oil supplies are available.
IRS ALIGNInitiates a rapid alignment of the inertial reference system.